Modell: Sightseeing Elevator
No. |
Basic Function |
No. |
Basic Function |
1 |
Full collective operation |
2 |
Inverter multiple protection |
3 |
Door detector function |
4 |
Landing display flashing prompt |
5 |
Non-entrance-opening protection outside the door |
6 |
Full load by-pass |
7 |
Anti-stall protection |
8 |
Overload protection |
9 |
Phase protection |
10 |
Anti-lock shorting protection |
11 |
Brake contactor detecting protection |
12 |
Terminal Anti-over travel protection |
13 |
Operation contactor detection protection |
14 |
Running direction in scroll display |
15 |
Floor nomination settings |
16 |
Prevent slipping protection |
17 |
Prevent reversal protection |
18 |
Service floor settings |
19 |
Automatic home landing |
20 |
Door open button response indicating |
21 |
Keep entrance opening time auto control |
22 |
Door close button response indicating |
23 |
Hall station exterior entrance opening |
24 |
Door open button response indicating |
25 |
Car reversal instruction elimination |
26 |
Dot matrix floor display |
27 |
Overload warning |
28 |
Hoistway self-learning data |
29 |
Parking function |
30 |
Auto revision of hall station signal |
31 |
Door open-closing blocked protection |
32 |
Intercom communication with alarm |
33 |
Inspection running |
34 |
Arrival gong |
35 |
Hall call function |
36 |
Emergency lighting |
37 |
Self-rescue operation |
38 |
Running timeout protection |
39 |
Arrival auto entrance |
40 |
Over speed protection |
41 |
Automatic close |
42 |
Numbers of running record |
43 |
Instant door close |
44 |
Error code display |
45 |
Open button for entrance opening |
46 |
Error history |
47 |
Failure Re-open |
48 |
Attendant operation |
49 |
Emergency return in case of fire |
50 |
Remote monitoring interface reserving |
51 |
Fireman operation function & reservation for fire fighting linkage interface |
52 |
Car lighting and ventilation energy conservation control |
53 |
Stainless steel panel/Stainless steel Braille buttons |
54 |
Car LED energy efficient illumination |
55 |
Five parties intercom |
56 |
Car call reset |
57 |
Humanized ultrahigh car configuration |
|
|
Load(kg) |
Number of Passenger |
Speed(m/s) |
Size Inside the Cabin(mm) |
Entrance Opening Width(mm) |
450 |
6 |
1.0/1.5/1.75 |
1400×900 |
800 |
630 |
8 |
1.0/1.5/1.75 |
1400×1200 |
800 |
800 |
10 |
1.0/1.5/1.75/2.0/3.0 |
1400×1400 |
800 |
1000 |
13 |
1.0/1.5/1.75/2.0/3.0 |
1600×1500 |
900 |
1250 |
16 |
1.0/1.5/1.75/2.0/3.0 |
2000×1400 |
1000 |
1350 |
18 |
1.0/1.5/1.75/2.0/3.0 |
2000×1500 |
1100 |
1600 |
21 |
1.0/1.5/1.75/2.0/3.0 |
2000×1700 |
1200 |
Load(kg) |
Hoistway Dimension(mm) |
Machine Room Dimension(mm) |
Pit Depth(m) |
Overhead(m) |
450 |
2300×1400 |
2300×1400 |
1.5/1.6/1.7 |
4.3/4.4/4.5 |
630 |
2300×1600 |
2300×1600 |
1.5/1.6/1.7 |
4.3/4.4/4.5 |
800 |
2300×1800 |
2300×1800 |
1.5/1.6/1.7/1.8/2.5 |
4.3/4.4/4.5/4.8/5.0 |
1000 |
2500×1900 |
2500×1900 |
1.5/1.6/1.7/1.8/2.5 |
4.3/4.4/4.5/4.8/5.0 |
1250 |
2900×1900 |
2900×1900 |
1.5/1.6/1.7/1.8/2.5 |
4.3/4.4/4.5/4.8/5.0 |
1350 |
2900×1900 |
2900×1900 |
1.5/1.6/1.7/1.8/2.5 |
4.3/4.4/4.5/4.8/5.0 |
1600 |
2900×2100 |
2900×2100 |
1.5/1.6/1.7/1.8/2.6 |
4.3/4.4/4.5/4.8/5.0 |
Produktgruppe : Panorama Aufzug